Reference - poredane po proizvodima

United Kingdon, Plymouth, Schneider Electrics Factory Floor




Objekt
VAP Moisture Mitigation System in Plymouth Factory 
Područja primjene
Sustav parnih brana (ispod podnih obloga)
Sanacija betonske konstrukcije
Injektiranje mokrih ili suhih pukotina pod pritiskom
Opis
Repair of a section of flooring badly affected by osmotic blistering. Problem fully investigated by taking test core sample and after analysis Koster Aquatecnic advised on a bespoke solution using Koster VAP 2000 FS to solve the problem of water vapour rising through the concrete slab and destroying the bond between the slab and the adhesive coating. The first step was to fill all cracks, potholes and voids with VAP FS 2000 and then shot blast and thoroughly clean the concrete slab. KB Pox IN was then used as a pre-treatment and finally, VAP 2000 FS was applied to a thickness of 0.36mm. VAP is a fast setting vapour barrier and can be over-coated in 2-3 hours allowing for overnight application.  
Korišteni proizvodi
KÖSTER KB-Pox IN
KÖSTER Ugušćivač
KÖSTER VAP I 2000 FS
Izvođač
Florock Ltd 
Odaberite proizvod:

 

 

Back

Top
Austria Brasil Bulgaria China Croatia Denmark Finland Germany Ghana Greece Hungary Italy Japan Kazakhstan Korea Kuwait Latvia Lebanon Mexico Netherlands Norway Panama Philippines Poland Portugal Romania Russia Senegal Serbia Slovakia Slovenia South Africa Thailand Turkey Ukraine United Kingdom United States of America